    摘 要:電力系統(tǒng)通信規(guī)約是變電站自動(dòng)化系統(tǒng)的重要組成部分,IEC 101規(guī)約已經(jīng)成為調(diào)度主站與廠站之間進(jìn)行通信的基本標(biāo)準(zhǔn)之一。介紹了IEC 101的規(guī)約結(jié)構(gòu)、報(bào)文格式,闡述了信息體的基本組成和主站對(duì)信息體地址進(jìn)行排序的說明;通過對(duì)3個(gè)實(shí)際案例進(jìn)行分析,進(jìn)一步闡述了101規(guī)約的使用規(guī)則和傳輸機(jī)制,對(duì)電氣系統(tǒng)繼電保護(hù)的定檢和消缺工作有一定的指導(dǎo)作用,有效提升了繼電保護(hù)工作的效率。
    關(guān)鍵詞:IEC 101規(guī)約;規(guī)約結(jié)構(gòu);信息體;案例分析
    中圖分類號(hào):TN915.04     文獻(xiàn)標(biāo)識(shí)碼:A     文章編號(hào):1007-3175(2018)06-0062-03
 
Structural Recognition and Case Analysis of IEC 101 Protocol
 
QIU Kai-xiang1, JIN Yu2
(1 Shenzhen Power Supply Co., Ltd, Shenzhen 518001, China;
2 School of Electrical Engineering, Xi’an Jiaotong University, Xi’an 710049, China)
 
    Abstract: The power system communication protocol is an important constituent part of substation automatic system. The IEC 101 protocol has become one of the basic standards scheduling communications between the primary station and the plant station. Introduction was made to the IEC 101 protocol structure and message format. This paper expounded the basic composition of informosomes and the illustration of sorting informosomes address. Three practical case examples were analyzed to further expound the service regulations of IEC 101 protocol and transmission mechanism, which has certain guidance function for the regular checking and defects eliminating work of relay protection in power system, so as to promote the efficiency of relay protection work.
    Key words: IEC 101 protocol; protocol structure; informosomes; case analysis
 
參考文獻(xiàn)
[1] 張保會(huì),尹項(xiàng)根. 電力系統(tǒng)繼電保護(hù)[M]. 2 版.  北京:中國電力出版社,2010.
[2] 徐攀,孟文,張彩英.101規(guī)約在SCADA系統(tǒng)中的應(yīng)用及實(shí)現(xiàn)[J]. 電氣應(yīng)用,2010,29(9) :42-45.
[3] 方鎮(zhèn)宏.IEC 60870-5-101規(guī)約在電站遠(yuǎn)動(dòng)通信中的應(yīng)用[J]. 黑龍江科技信息,2009(32) :16.
[4] 李翔,張學(xué)剛,任濤,等. 基于101規(guī)約的智能分析軟件設(shè)計(jì)與實(shí)現(xiàn)[J]. 電力信息安全專家,2013,11(11) :87-91.
[5] 華北電網(wǎng)有限公司電力調(diào)度通信中心. IEC 60870-5系列協(xié)議應(yīng)用指南[M]. 北京:中國電力出版社,2008.
[6] 國家電力調(diào)度通信中心. 國家電網(wǎng)繼電保護(hù)培訓(xùn)教材[M]. 北京:中國電力出版社,2009.