核電站嚴(yán)重事故下電氣貫穿件鑒定的研究

來源:電工電氣發(fā)布時(shí)間:2019-06-13 13:13 瀏覽次數(shù):756
核電站嚴(yán)重事故下電氣貫穿件鑒定的研究
 
俞高偉1,馬濤2,孫健1,萬青1,吳珂科1
(1 上海發(fā)電設(shè)備成套設(shè)計(jì)研究院有限責(zé)任公司,上海 200240;2 上海核工程研究設(shè)計(jì)院有限公司,上海 200233)
 
    摘 要:設(shè)備鑒定是核電站安全的重要保證。介紹了核電站安全殼電氣貫穿件,研究了電氣貫穿件的相關(guān)標(biāo)準(zhǔn),比較了不同標(biāo)準(zhǔn)在嚴(yán)重事故下對電氣貫穿件的鑒定要求,并結(jié)合AP1000、EPR、華龍一號(hào)等三代核電站的具體實(shí)踐,明確電氣貫穿件嚴(yán)重事故條件下的鑒定實(shí)施,為核電站其他設(shè)備鑒定提供了借鑒。
    關(guān)鍵詞:核電站;電氣貫穿件;嚴(yán)重事故;設(shè)備鑒定
    中圖分類號(hào):TM623     文獻(xiàn)標(biāo)識(shí)碼:A     文章編號(hào):1007-3175(2019)06-0063-04
 
Study on Qualification of Electric Penetration Assembly under Severe Accidents in Nuclear Power Plant
 
YU Gao-wei1, MA Tao2, SUN Jian1, WAN Qing1, WU Ke-ke1
(1 Shanghai Power Equipment Research Institute Co., Ltd, Shanghai 200240, China;
2 Shanghai Nuclear Engineering Research and Design Institute Co., Ltd, Shanghai 200233, China)
 
    Abstract: Qualification of equipment is an important guarantee for nuclear power plants. Introduction was made to the containment electric penetration assembly in nuclear power station. This paper studied the relevant standards of the electrical penetration assembly, compared to the identification requirements of the electrical penetration assembly in different standards about severe accidents, and combined with the concrete practice of the three generations of nuclear power plants such as AP1000, EPR, Hua-long No. 1 etcthree generations nuclear power station concrete practice. The qualification and implementation under the condition of severe accident of electrical penetrating parts were clarified to provide references for the qualification of other equipment in nuclear power plant.
    Key words: nuclear power plant; electric penetration assembly; severe accidents; qualification of equipment
 
參考文獻(xiàn)
[1] 國家核安全局. 核動(dòng)力廠設(shè)計(jì)安全規(guī)定:HAF 102—2016[S]. 北京:法律出版社,2016:28-29.
[2] 龔釗,李棟梁. 三代核電站嚴(yán)重事故下設(shè)備鑒定的研究[J]. 中國高新技術(shù)企業(yè),2013(24):104-106.
[3] 孫造占,初起寶,房永剛,張?jiān)撇? 嚴(yán)重事故下設(shè)備可用性論證要求[J]. 核安全,2014,13(1):20-27.
[4] 鄭開云,楊曉,陳智. 基于IEEE標(biāo)準(zhǔn)的電氣貫穿件鑒定試驗(yàn)研究[J]. 核安全,2016,15(2):70-76.
[5] Nuclear Power Engineering Committee.IEEE Standard for Electric Penetration Assemblies in Containment Structures for Nuclear Power Generating Stations:IEEE 317—2013[S].New York: IEEE Standard Association,2013:18-19.
[6] AFCEN.Design and Construction Rules for Electrical Components of Nuclear Islands: RCC-E 2005[S].Paris: French Society for Design and Construction Rules for Nuclear Island Components,2005:54-55.