Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 文章瀏覽排名

AP1000核電廠中壓廠用電源切換設(shè)計及優(yōu)化

來源:電工電氣發(fā)布時間:2019-06-13 14:13 瀏覽次數(shù):799
AP1000核電廠中壓廠用電源切換設(shè)計及優(yōu)化
 
姚鐵兵1,張會國2,夏曉磊1
(1 山東核電有限公司,山東 煙臺 265116;2 國網(wǎng)山西省電力公司運(yùn)城供電公司,山西 運(yùn)城 044000)
 
    摘 要:介紹了AP1000核電廠的電氣系統(tǒng)及中壓廠用電源切換的設(shè)計特點,對核電、常規(guī)火電的廠用電切換設(shè)計進(jìn)行了差異比較,分析了AP1000核電在非正常運(yùn)行方式下的中壓廠用電源切換特點及設(shè)計優(yōu)化過程。通過設(shè)計優(yōu)化,取消了輔助鍋爐運(yùn)行閉鎖廠用電快切,并提出了相關(guān)建議,為后續(xù)AP1000工程提供參考。
    關(guān)鍵詞:核電廠;中壓廠用電源;切換設(shè)計
    中圖分類號:TM623     文獻(xiàn)標(biāo)識碼:B     文章編號:1007-3175(2019)06-0028-06
 
Design & Optimization of Medium Voltage Buses Transfer in AP1000 Nuclear Power Plant
 
YAO Tie-bing1, ZHANG Hui-guo2, XIA Xiao-lei1
(1 Shandong Nuclear Power Company Ltd, Yantai 26511 6, China;
2 Yuncheng Power Supply Company of State Grid Shanxi Electric Power Company, Yuncheng 044000, China)
 
    Abstract: Introduction was made to the design characteristic of the electrical system and medium voltage buses transfer of AP1000 nuclear power plant. This paper compared the difference of medium voltage buses transfer between nuclear power plant and normal thermal power plant and analyzed the medium voltage buses transfer characteristic and design optimization procedure of AP1000 nuclear power under abnormal operation mode. Via design optimization, the buses transfer wasn’t be blocked any longer when auxiliary boilers were in operation. This paper gave the relevant suggestion, which provides references for the follow-up AP1000 project.
    Key words: nuclear power plant; medium voltage buses transfer; switch design
 
參考文獻(xiàn)
[1] 王林暉, 苗偉東, 李忠全. 首批A P1000機(jī)組廠用電切換設(shè)計分析及改進(jìn)建議[J]. 機(jī)電信息,2014(30):131-135.
[2] 電力行業(yè)繼電保護(hù)標(biāo)準(zhǔn)化技術(shù)委員會. 電廠廠用電源快速切換裝置通用技術(shù)條件:DL/T 1073—2007[S]. 北京:中國電力出版社,2008:5-8.
[3] 王新. 火電機(jī)組工作與備用電源為兩電網(wǎng)的廠用電切換[J]. 科技情報開發(fā)與經(jīng)濟(jì),2011,21(28):181-184.
[4] 公方濤. 淺談SID-8BT-A備用電源快速切換裝置原理及應(yīng)用技術(shù)[J]. 科技創(chuàng)新導(dǎo)報,2013(15):253-254.
[5] 任少義. AP1000核電廠孤島運(yùn)行廠用電源同期切換研究[J]. 電氣技術(shù),2017(9):57-60.