來源:電工電氣發(fā)布時間:2020-12-19 10:19 瀏覽次數(shù):691
一起中壓故障電纜識別的事故分析
 
董海疆,林曉冬,唐毓,董恒,周晉輝,尹恒陽
(國網(wǎng)四川省電力公司成都市高新供電分公司,四川 成都 610093)
 
    摘 要:針對運維檢修人員在配電電纜上操作時可能導致觸電、爆炸等嚴重后果的情況,介紹了一起中壓故障電纜識別事故,闡述了停電電纜識別原理及停電電纜識別的接線方法,并從電纜路徑探測和電纜識別兩方面分析了本次的事故原因。結(jié)合實際情況,提出了保障故障電纜正確識別并防止電網(wǎng)安全生產(chǎn)事故發(fā)生的幾點建議,為電纜識別相關工作的人員提供參考。
    關鍵詞:電纜識別;配電網(wǎng);路徑探測;故障定位
    中圖分類號:TM726.4;TM755     文獻標識碼:B     文章編號:1007-3175(2020)12-0047-05
 
Accident Analysis of a Medium Voltage Fault Cable Identification
 
DONG Hai-jiang, LIN Xiao-dong, TANG Yu, DONG Heng, ZHOU Jin-hui, YIN Heng-yang
(State Grid Sichuan Electric Power Company Chengdu High-Tech Power Supply Branch, Chengdu 610093, China)
 
    Abstract: In view of the situation that operation and maintenance personnel may cause serious consequences such as electric shock and explosion when operating on the power distribution cable. This paper introduces a medium-voltage faulty cable identification accident, expounds the power failure cable identification principle and the wiring method of the power failure cable identification, and analyzes the cause of the accident from two aspects of cable path detection and cable identification. Based on the actual situation, several suggestions are put forward to ensure the correct identification of faulty cables and prevent the occurrence of safety production accidents in the power grid, and provide references for personnel working on cable identification.
    Key words: cable identification; power distribution network; path detection; locate fault
 
參考文獻
[1] 高樹國,劉賀晨,范輝,等. 考慮波速特性的小波變換模極大值法的電力電纜局部放電定位研究[J].電網(wǎng)技術,2016,40(7):2244-2250.
[2] ZHU K, LEE W K, PONG P W T.Energization-Status Identification of Three-Phase Three-Core Shielded Distribution Power Cables Based on Non-Destructive Magnetic Field Sensing[J].IEEE Sensors Journal,2017,17(22):7405-7417.
[3] ANDERS G J.Rating of Electric Power Cables in Unfavorable Thermal Environment[M].New York:Wiley,2005.
[4] BERTLING L, ALLAN R, ERIKSSON R.A reliabilitycentered asset maintenance method for assessing the impact of maintenance in power distribution systems[J].IEEE Transactions on Power System,2005,20(1):75-82.
[5] 邢偉,琚澤立,侯喆,等. 開閉所內(nèi)電纜局部放電故障的帶電檢測與診斷[J]. 電氣應用,2020,39(10):39-44.
[6] UKIL A, BRAENDLE H, KRIPPNER P.Distributed Temperature Sensing: Review of Technology and Applications[J].IEEE Sensors Journal,2012,12(5):885-892.
[7] BHUIYAN R H, DOUGAL R A, ALI M.Proximity Coupled Interdigitated Sensors to Detect Insulation Damage in Power System Cables[J]. IEEE Sensors Journal,2007,7(12):1589-1596.
[8] LI Fangxing, QIAO Wei, SUN Hongbin, et al.Smart Transmission Grid: Vision and Framework[J]. IEEE Transactions on Smart Grid,2010,1(2):168-177.
[9] JIANG Bing, SAMPLE A P, WISTORT R M, et al. Autonomous robotic monitoring of underground cable systems [C]//12th International Conference on Advanced Robotics,2005.
[10] SHORT S X, MAMISHEV A V, KAO T W, et al. Evaluation of methods for discrimination of energized underground power cables[J]. Electric Power Systems Research,1996,37(1):29-38.
[11] 楊勻陽,賴志松,葉斌,等. 低壓電纜線路快速識別方法[J]. 電氣工程應用,2019(1):6-10.
[12] 郭志強,楊晉偉,秦路路. 故障電纜快速識別方法的探討[J]. 電世界,2019,60(3):31-32.
[13] 羅義暉,楊雪飛,歐俊延,等. 變電站內(nèi)電纜識別方法的探討[J]. 電工技術,2019(4):62-63.
[14] 張志利,黃亮,侯傳勛. 裝備電纜的故障檢測[J].兵工自動化,2007,26(4):91-92.
[15] 顧金,錢忠,楊維榮. 帶電電纜識別儀在低壓電纜臺區(qū)普查工作中的應用研究[J]. 電力與能源,2018,39(3):320-323.
[16] 姚雷明,王輝,張梁,等. 一起高壓單芯電纜故障定位和原因分析[J]. 現(xiàn)代工業(yè)經(jīng)濟和信息化,2018,8(4):92-94.
[17] 楊志義, 徐明良, 李紅巖. 基于物聯(lián)網(wǎng)與大數(shù)據(jù)技術的多電纜識別[J]. 電子技術與軟件工程,2018(14):169.