significantly reduce the harmonic distortion of the supply voltage of the ac-dc-ac traction substation.
參考文獻
[1] 常非,楊中平,林飛. 基于 MMC 的新型牽引供電系統(tǒng)研究 (一) [J]. 鐵道學報,2016,38(12) :41-46.
[2] 常非,楊中平,林飛. 基于 MMC 的新型牽引供電系統(tǒng)研究 (二) [J]. 鐵道學報,2017,39(2) :39-43.
[3] HE Xiaoqiong,SHU Zeliang,PENG Xu, et al.Advanced Cophase Traction Power Supply System Based on Three-Phase to Single-Phase Converter[J].IEEE Transactions on Power Electronics,2014,29(10) :5323-5333.
[4] 夏焰坤,李群湛,解紹鋒,等. 電氣化鐵道貫通同相供電變電所控制策略研究[J] . 鐵道學報,2014,36(8) :25-31.
[5] 陳民武,宮衍圣,李群湛,等. 電氣化鐵路電能質(zhì)量評估及新型控制方案研究[J] . 電力系統(tǒng)保護與控制,2012,40(16) :141-147.
[6] 李強,吳命利. 交流傳動機車與直流傳動機車混合運用條件下牽引網(wǎng)電壓控制技術[J] . 鐵道學報,2014,36(8),19-24.
[7] 邢亭婷. 同相牽引供電系統(tǒng)能耗研究[J] . 節(jié)能技術,2017,35(3) :279-282.
[8] 王子江. 國內(nèi)外諧波限值標準綜述及展望[C]// 全國電壓電流等級和頻率標準化技術委員會第九屆電能質(zhì)量研討會論文集,2018 :18.
[9] ZANOTTO L, PIOVAN R, TOIGO V, et al.Filter design for harmonic reduction in high-voltage booster for railway applications[J].IEEE Transactions on Power Delivery,2005,20(1) :258-263.
[10] 桂衛(wèi)華,張定華,薛蛟. 基于大容量 SVC 的 SCOTT 變壓器電能質(zhì)量治理方案及應用[J] . 鐵道學報,2011,33(1) :31-38.
[11] BUENO A, ALLER J M, RESTREPO J A, et al.Harmonic and Unbalance Compensation Based on Direct Power Control for Electric Railway Systems[J] . IEEE Transactions on Power Electronics,2013,28(12) :5823-5831.
[12] TAN Pee-Chin, LOH Poh Chiang, HOLMES Grahame.Optimal impedance termination of 25-kV electrified railway systems for improved power quality[J].IEEE Transactions on Power Delivery,2005,20(2) :1703-1710.
[13] 趙偉,羅安,曹一家,等. 三相- 兩相牽引變電所用無功動態(tài)補償與諧波治理混合系統(tǒng)的研究[J] .中國電機工程學報,2009,29(28) :107-114.
[14] 王躍,楊君,王兆安,等. 電氣化鐵路用混合電力濾波器的研究[J] . 中國電機工程學報,2003,23(7) :23-27.
[15] 程軍照,李澍森,吳在軍,等. 微電網(wǎng)下垂控制中虛擬電抗的功率解耦機理分析[J] . 電力系統(tǒng)自動化,2012,36(7) :27-32.
[16] HOU Guolian, XING Fulin, YANG Yu, et al.Virtual negative impedance droop method for parallel inverters in microgrids[C]//2015 IEEE 10th Conference on Industrial Electronics and Applications ( ICIEA ),2015 :1009-1013.
[17] HE Jinwei, LI Yunwei, BOSNJAK Dubravko,et al.Investigation and Active Damping of Multiple Resonances in a Parallel-Inverter-Based Microgrid[J].IEEE Transactions on Power Electronics,2013,28(1) :234-246.
[18] HE Jinwei, LI Yunwei.Analysis, Design, and Implementation of Virtual Impedance for Power Electronics Interfaced Distributed Generation[J].IEEE Transactions on Industry Applications,2011,47(6) :2525-2538.
[19] GUERRERO Josep M, BERBEL Nestor, MATAS Jose,et al.Decentralized Control for Parallel Operation of Distributed Generation Inverters Using Resistive Output Impedance[J].IEEE Transactions on Industrial Electronics,2007,54(2) :994-1004.
[20] PLET Cornelis A, GREEN Timothy C.A method of voltage limiting and distortion avoidance for islanded inverter-fed networks under fault[C]//Proceedings of the 2011 14th European Conference on Power Electronics andApplications,2011 :1-8.
[21] CHEN Hsin-Chih, KO Hsin-Cheng, CHENG Po-Tai.An inrush current mitigation method for the grid-connected converters in the low-voltage ride-through operation[C]//2013 IEEE Energy Conversion Congress and Exposition,2013 :1717-1724.
[22] BHATTACHARYA S, CHENG Po-Tai, DIVAN D M.Hybrid solutions for improving passive filter performance in high power applications[J].IEEE Transactions on Industry Applications,1997,33(3) :732-747.