基于IEC標準的核電廠中壓斷路器暫態(tài)恢復電壓研究

來源:電工電氣發(fā)布時間:2023-02-06 13:06 瀏覽次數(shù):340

基于IEC標準的核電廠中壓斷路器暫態(tài)恢復電壓研究

夏曉磊1,鄭海龍1,宋光耀2
(1 山東核電有限公司,山東 煙臺 265116;
2 中國聯(lián)合重型燃氣輪機技術有限公司,北京 100016)
 
    摘 要:對比分析了 IEC 標準和 IEEE 標準對斷路器耐受暫態(tài)恢復電壓(TRV)的要求?;?IEC 62271 標準關于斷路器在特定電路中耐受 TRV 的特殊要求,收集某核電廠的廠用變壓器、共箱母線等設備參數(shù),利用 IEC 標準中的計算方法得出耐受 TRV 和恢復電壓上升速率(RRRV)的理論值(預期值)。通過斷路器的 T60 型式試驗,驗證了 VD4 斷路器滿足耐受 TRV 的要求。
    關鍵詞: IEC 標準;核電廠;中壓斷路器;暫態(tài)恢復電壓;T60 型式試驗
    中圖分類號:TM561     文獻標識碼:A     文章編號:1007-3175(2023)01-0063-04
 
Research on Transient Recovery Voltage of Middle-Voltage Circuit
Breaker in a Nuclear Power Plant Based on IEC Standard
 
XIA Xiao-lei1, ZHENG Hai-long1, SONG Guang-yao2
(1 Shandong Nuclear Power Co., Ltd, Yantai 265116, China;
2 China United Gas Turbine Technology Co., Ltd, Beijing 100016, China)
 
    Abstract: The paper makes comparative analysis of the requirements of circuit breakers tolerant transient recovery voltage (TRV) in IEC standard and IEEE standard. The authors based on the IEC 62271 special requirements of circuit breakers tolerant TRV in special circuits,collect parameters of auxiliary transformers, common enclosure buses and other equipments in a nuclear power plant, and apply the calculation method from IEC standard to get the theoretical values (expected values) of tolerant TRV and transient recovery voltage rising rate (RRRV).It is verified by T60 type test of circuit breakers that the VD4 circuit breaker meets the requirements of tolerant TRV.
    Key words: IEC standard; nuclear power plant; middle-voltage circuit breaker; transient recovery voltage; T60 type test
 