密封油內(nèi)滲導(dǎo)致的轉(zhuǎn)子匝間絕緣劣化診斷

來源:電工電氣發(fā)布時間:2024-02-01 08:01 瀏覽次數(shù):218

密封油內(nèi)滲導(dǎo)致的轉(zhuǎn)子匝間絕緣劣化診斷

馮宇哲1,潘建偉2,王新3,楊立川1
(1 國網(wǎng)浙江省電力有限公司電力科學研究院,浙江 杭州 310014;
2 浙江浙能臺州第二發(fā)電有限責任公司,浙江 臺州 318016;
3 浙江浙能技術(shù)研究院有限公司,浙江 杭州 311121)
 
    摘 要:密封油內(nèi)滲導(dǎo)致轉(zhuǎn)子匝間絕緣劣化,是轉(zhuǎn)子匝間短路故障的主要原因之一。某臺 1 050 MW 汽輪發(fā)電機在運行狀態(tài)和極間電壓試驗均無異常的情況下,通過分析重復(fù)脈沖試驗結(jié)果,判斷轉(zhuǎn)子繞組已存在由密封油內(nèi)滲導(dǎo)致的轉(zhuǎn)子匝間絕緣劣化問題;拔出轉(zhuǎn)子護環(huán),發(fā)現(xiàn)轉(zhuǎn)子端部繞組區(qū)域存在大量密封油內(nèi)滲現(xiàn)象,同時轉(zhuǎn)子匝間絕緣未發(fā)生金屬性短路;對匝間絕緣劣化的機理進行了闡述并給出了檢修策略,以避免類似問題的再次發(fā)生。
    關(guān)鍵詞: 發(fā)電機;轉(zhuǎn)子繞組;密封油內(nèi)滲;匝間絕緣劣化
    中圖分類號:TM311     文獻標識碼:B     文章編號:1007-3175(2024)01-0055-04
 
Diagnosis of Rotor Interturn Insulation Deterioration
Caused by Seal Oil Infiltration
 
FENG Yu -zhe1, PAN Jian-wei2, WANG Xin3, YANG Li-chuan1
(1 State Grid Zhejiang Electric Power Co., Ltd. Electric Power Research Institute, Hangzhou 310014, China;
2 Zhejiang Zheneng Taizhou Second Electric Power Generation Co., Ltd, Taizhou 318016, China;
3 Zhejiang Zheneng Technology Research Institute Co., Ltd, Hangzhou 311121, China)
 
    Abstract: The sealing oil internal leakage leads to the degradation of generator rotor inter-turn insulation, which is one of the main reasons for rotor inter-turn short circuit faults. In this paper, a 1 050 MW steam turbine generator is taken as an example, and there is no abnormality in its operating state and interpolar voltage test, it was judged that the rotor winding had multi-point inter-turn insulation deterioration caused by sealing oil infiltration by analyzing the results of repeated pulse tests. When the rotor retainer ring was pulled out, it found that there was a large amount of sealing oil infiltration in the winding area at the end of the rotor, and there was no metallic short circuit in the insulation between the rotor turns; the mechanism of inter turn insulation degradation was explained and maintenance strategies were provided to avoid similar problems from happening again.
    Key words: generator; rotor winding; seal oil infiltration; interturn insulation deterioration
 
參考文獻
[1] 牟春華,居文平,黃嘉駟,等. 火電機組靈活性運行技術(shù)綜述與展望[J]. 熱力發(fā)電,2018,47(5) :1-7.
[2] 薛信春.600 MW 發(fā)電機轉(zhuǎn)子匝間短路的分析與處理[J]. 華東電力,2001,29(8) :28-29.
[3] 馮宇哲,羅統(tǒng)領(lǐng),金泱,等. 一起 RSO 檢測無效的大型隱極同步電機轉(zhuǎn)子動態(tài)匝間短路故障檢測與處理[J]. 大電機技術(shù),2023(2) :30-34.
[4] 郗常驥. 汽輪發(fā)電機故障實例與分析[M]. 北京:中國電力出版社,2002.
[5] 關(guān)建軍. 大型汽輪發(fā)電機轉(zhuǎn)子繞組匝間短路故障的診斷研究[J]. 大電機技術(shù),2003(2) :18-22.
[6] 馮宇哲,李衛(wèi)軍,楊立川.660 MW 發(fā)電機轉(zhuǎn)子繞組匝間短路故障檢測與處理[J]. 電工電氣,2023(7) :46-50.
[7] 李永剛,李和明,趙華. 汽輪發(fā)電機轉(zhuǎn)子繞組匝間短路故障診斷新判據(jù)[J] . 中國電機工程學報,2003,23(6) :112-116.
[8] 李曉明,劉東明. 大型汽輪發(fā)電機轉(zhuǎn)子繞組匝間短路故障的測試與分析[J]. 大電機技術(shù),2003(3) :7-11.
[9] 凌霜寒,黃立軍,米賢才,等. 基于重復(fù)脈沖法的轉(zhuǎn)子繞組匝間短路故障診斷[J] . 浙江電力,2016,35(8) :42-45.
[10] ALBRIGHT D R.Interturn Short-Circuit Detector for Turbine Generator Rotor Windings[J].IEEE Transactions on Power Apparatus and Systems,1971,PAS-90(2) :478-483.
[11] 中國電力企業(yè)聯(lián)合會. 隱極同步發(fā)電機轉(zhuǎn)子匝間短路故障診斷導(dǎo)則:DL/T 1525—2016[S]. 北京:中國電力出版社,2016 :4-6.
[12] 中國機械工業(yè)聯(lián)合會. 隱極式同步發(fā)電機轉(zhuǎn)子匝間短路測定方法:JB/T 8446—2013[S]. 北京:機械工業(yè)出版社,2013 :3-8.
[13] 馮宇哲,孫海軍,柯元豐,等. 發(fā)電機氫氣純度偏低的治理和典型氫氣提純裝置的應(yīng)用[J] . 電工電氣,2021(7) :39-43.