高壓電機(jī)定子繞組絕緣薄弱點(diǎn)定位方法的研究

來源:電工電氣發(fā)布時間:2016-03-14 16:14 瀏覽次數(shù):12

高壓電機(jī)定子繞組絕緣薄弱點(diǎn)定位方法的研究 

吳磊1,莫岳平1,龔維明2 
(1 揚(yáng)州大學(xué) 水利與能源動力工程學(xué)院,江蘇 揚(yáng)州 225127;
2 江蘇省江都水利工程管理處,江蘇 揚(yáng)州 225200)
 
 

摘 要:針對現(xiàn)有局部放電檢測法不能解決高壓電機(jī)定子繞組絕緣薄弱點(diǎn)的定位問題,研究了絕緣薄弱點(diǎn)在局放下產(chǎn)生電場信號的特點(diǎn),設(shè)計(jì)了手持式局放定位探測器。通過與局放儀配合使用,有效解決了高壓電機(jī)定子繞組絕緣薄弱點(diǎn)定位問題。試驗(yàn)結(jié)果表明:該裝置能準(zhǔn)確定位電機(jī)定子端部的絕緣薄弱點(diǎn)位置,從而避免電機(jī)絕緣故障的進(jìn)一步擴(kuò)大。
關(guān)鍵詞:高壓電機(jī);局部放電;絕緣薄弱點(diǎn)定位;定位探測器
中圖分類號:TM305.2 文獻(xiàn)標(biāo)識碼:A 文章編號:1007-3175(2016)01-0044-05


Research on Positioning Method of High-Voltage Motor Stator Winding Insulation Vulnerabilities 

WU Lei1, MO Yue-ping1, GONG Wei-ming2 
(1 School of Hydraulic, Energy and Power Engineering, Yangzhou University, Yangzhou 225127, China;
2 Jiangdu Water Control Project Management Office of Jiangsu Province, Yangzhou 225200, China)
 
 

Abstract: In allusion to the problem that the existing partial discharge detection method cannot locate the motor stator winding insulation vulnerabilities, this paper researched the winding insulation vulnerabilities which produced an electric field under the partial discharge signals and designed a handheld partial discharge positioning detector. Cooperated with the partial discharge detector, the positioning problem of high-voltage motor stator winding insulation vulnerabilities could be solved effectively. The experimental results show that the detector can accurately locate the insulation vulnerabilities position at motor stator ends, so as to reduce the risk of motor problems due to the insulation fault.
Key words: high-voltage motor; partial discharge; insulation vulnerabilities positioning; position detector


參考文獻(xiàn)
[1] 劉蓉. 超聲技術(shù)在變壓器局部放電檢測中的應(yīng)用[J]. 電子元器件應(yīng)用,2009,11(6):78-79.
[2] 蘭云鵬. 電力變壓器局部放電檢測定位的研究[D].沈陽:沈陽工業(yè)大學(xué),2009.
[3] 汪泉弟,楊承河,楊永明,等. 發(fā)電機(jī)定子繞組局部放電超聲波在線定位分析[J]. 重慶大學(xué)學(xué)報(bào):自然科學(xué)版,2009,32(10):1150-1153.
[4] 徐敏驊,裘簡濤. 聲電聯(lián)合技術(shù)在局部放電檢測中的應(yīng)用[J]. 上海電力,2011,24(1):70-73.
[5] 林波,程珩. 多傳感器信息融合在電機(jī)絕緣故障診斷中的應(yīng)用[J]. 機(jī)械工程與自動化,2007(2):106-108.
[6] 白國興. 局部放電脈沖極性鑒別法在變壓器高壓絕緣故障定位分析中的應(yīng)用[C]// 全國電工測試技術(shù)學(xué)術(shù)交流會論文集,2002:90-92.
[7] 于宏濱. 基于D S P 的變壓器局部放電信號在線采集系統(tǒng)的設(shè)計(jì)[D]. 沈陽:沈陽工業(yè)大學(xué),2008.