南通沿海風(fēng)電對(duì)電網(wǎng)電能質(zhì)量影響的研究

來(lái)源:電工電氣發(fā)布時(shí)間:2016-03-15 10:15 瀏覽次數(shù):574

南通沿海風(fēng)電對(duì)電網(wǎng)電能質(zhì)量影響的研究 

張彥1,劉彬彬2 
1 江蘇省電力公司檢修分公司,江蘇 南通 226006; 2 南通供電公司,江蘇 南通 226006 
 

摘 要:以南通沿海風(fēng)電場(chǎng)對(duì)電網(wǎng)的影響為例,分析了因風(fēng)電導(dǎo)致電能質(zhì)量問題的產(chǎn)生機(jī)理,并利用現(xiàn)場(chǎng)測(cè)試數(shù)據(jù)進(jìn)行了考核。結(jié)果顯示,風(fēng)電出力的隨機(jī)性和波動(dòng)性給電網(wǎng)的運(yùn)行控制帶來(lái)了不確定性,且造成各種電能質(zhì)量問題。提出了若干應(yīng)時(shí)措施,以期降低風(fēng)電接入系統(tǒng)后對(duì)電能質(zhì)量的影響,保證沿海風(fēng)電大規(guī)模接入后電網(wǎng)的安全、穩(wěn)定、經(jīng)濟(jì)運(yùn)行。

關(guān)鍵詞:沿海風(fēng)電;電能質(zhì)量;影響

中圖分類號(hào):TM614 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1007-3175(2013)02-0013-03


Study of Impacts of Nantong Coastal Wind Power on Grid Power Quality 

ZHANG Yan1, LIU Bin-bin2 
1 Jiangsu Power Company Maintenance Branch, Nantong 226006, China; 2 Nantong Power Supply Company, Nantong 226006, China 
 

Abstract: Taking impacts of Nantong coastal wind power on grid for example, this paper analyzed generation mechanism of power quality problems due to wind power and carried out examination by using site test data. The result shows that the randomness and uncontrollability of wind power output causes uncertainty and various kinds of power quality problems. Some counterpart measures are raised, so as to reduce the impacts on power quality after wind power is connected in the system, to ensure safe, stable and economic operation of grid after coastal wind power connected in large scale.
Key words: coastal wind power; power quality; impact


參考文獻(xiàn)
[1] 孫榮富,張濤,梁吉.電網(wǎng)接納風(fēng)電能力的評(píng)估及應(yīng)用[J].電力系統(tǒng)自動(dòng)化,2011,35(4):70-76. 
[2] 曹娜,趙海翔,戴慧珠.常用風(fēng)電機(jī)組并網(wǎng)運(yùn)行時(shí)的無(wú)功與電壓分析[J].電網(wǎng)技術(shù),2006,30(22):91-94.
[3] 陳寧,朱凌志,王偉.改善接入地區(qū)電壓穩(wěn)定性的風(fēng)電場(chǎng)無(wú)功控制策略[J].中國(guó)電機(jī)工程學(xué)報(bào),2009,29(10):102-108.
[4] 項(xiàng)真,解大,龔錦霞,張延遲.用于風(fēng)電場(chǎng)無(wú)功補(bǔ)償?shù)腟TATCOM動(dòng)態(tài)特性分析[J].電力系統(tǒng)自動(dòng)化,2008,32(9):92-95.
[5] 高宗和,滕賢亮,張小白.適應(yīng)大規(guī)模風(fēng)電接入的互聯(lián)電網(wǎng)有功調(diào)度與控制方案[J].電力系統(tǒng)自動(dòng)化,2010,34(17):37-41.
[6] 袁曉冬.東凌風(fēng)場(chǎng)電能質(zhì)量報(bào)告[R].南京:江蘇省電力公司電力科學(xué)研究院,2012.