兩路電源供電的三繞組變壓器的設(shè)計
陳伯根
福州天宇電氣股份有限公司,福建 福州 350012
摘 要:給出了兩路電源供電的梯級小水電站變壓器的兩種設(shè)計方案,分析了采用三繞組變壓器作為主變的優(yōu)點。對三繞組變壓器的額定容量、電壓比、聯(lián)結(jié)組別、阻抗電壓等關(guān)鍵參數(shù)的選取進行了介紹,并對三繞組變壓器的結(jié)構(gòu)和外部平面布置進行了改進。經(jīng)實例驗證,采用改進后的三繞組變壓器的設(shè)計方案簡化了水電站的整體布置,經(jīng)濟性和節(jié)能效果良好。
關(guān)鍵詞:兩路電源供電;三繞組變壓器;結(jié)構(gòu)設(shè)計
中圖分類號:TM402 文獻標識碼:B 文章編號:1007-3175(2013)10-0027-04
Design of Duplicate Power Supply Three-Winding Transformer
CHEN Bo-gen
Fuzhou Tianyu Electric Co., Ltd, Fuzhou 350012, China
Abstract: Two kinds of design plans were given for cascade small hydropower station’s transformer of duplicate power supply. Analysis was made to the advantages of adopting three-winding transformer as main transformer. Introduction was made to the selection of rated capacity, voltage ratio, vector group, impedance voltage etc key parameters for three-winding transformer, and improvement was made to structure and external plane layout of three-winding transformer. After verification of actual examples, the design plan adopting improved three-winding transformer has simplified hydropower station’s integrated layout, and economy and energy saving effect are fine.
Key words: duplicate power supply; three-winding transformer; structure design