Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 文章瀏覽排名

含雙饋風(fēng)電機組風(fēng)水電聯(lián)合系統(tǒng)的穩(wěn)定性分析

來源:電工電氣發(fā)布時間:2016-04-05 16:05 瀏覽次數(shù):740

含雙饋風(fēng)電機組風(fēng)水電聯(lián)合系統(tǒng)的穩(wěn)定性分析 

劉淼淼,郭琰,陳江濤 
三門峽供電公司,河南 三門峽 472000 
 

摘 要: 介紹了風(fēng)電場接入電網(wǎng)運行后對電力系統(tǒng)穩(wěn)定性的影響。結(jié)合三門峽地區(qū)電網(wǎng)的實際情況,在具體算例數(shù)據(jù)的基礎(chǔ)上建立相關(guān)系統(tǒng)元件的數(shù)學(xué)模型,采用模型仿真與數(shù)據(jù)分析相結(jié)合的方法對含雙饋風(fēng)電機組風(fēng)水電聯(lián)合系統(tǒng)的穩(wěn)定性進(jìn)行了研究。結(jié)果表明雙饋風(fēng)電機組的接入降低了系統(tǒng)原有的阻尼,為系統(tǒng)引入了相關(guān)的振蕩模態(tài),分析研究成果對三門峽地區(qū)電網(wǎng)調(diào)度運行具有指導(dǎo)意義。
關(guān)鍵詞: 雙饋風(fēng)電機組;水輪發(fā)電機組;系統(tǒng)穩(wěn)定性;振蕩模態(tài);Prony 算法
中圖分類號:TM315 文獻(xiàn)標(biāo)識碼:A 文章編號:1007-3175(2013)11-0020-05


Stability Analysis of Wind-Hydro-Electric Combined System with Doubly-Fed Wind Generator Unit 

LIU Miao-miao, GUO Yan, CHEN Jiang-tao 
Sanmenxia Power Supply Company, Sanmenxia 472000, China 
 

Abstract: Introduction was made to the impact on power system stability after wind farm connection to power grid operation. Combined with actual situation of Sanmenxia area grid, this paper established the relevant system element mathematical model based on specific calculation example data. The model simulation was combined with data analysis to research on the stability of wind-hydroelectric combined system with doubly-fed wind generator unit. The result shows that connection-in of double-fed wind generator unit has reduced original damping of power system and introduces related oscillation mode for the system. The analysis study achievement has guiding significance for Sanmenxia area grid dispatching.
           Key words: doubly-fed wind generator unit; hydro-generator unit; stability of power system; oscillation mode; Prony algorithm


參考文獻(xiàn)
[1] 遲永寧,劉燕華,王偉勝,等.風(fēng)電接入對電力系統(tǒng)的影響[J].電網(wǎng)技術(shù),2007,31(3):77-81.
[2] Akhmatov Vladisav.An aggregate model of a grid-connected, large scale, offshore wind farm for power stability investigationsimportance of windmill mechanical system[J].International Journal of Electrical Power & Energy System, 2002, 24(9):709-717.
[3] 郝正航, 余貽鑫. 雙饋風(fēng)力發(fā)電機組對電力系統(tǒng)穩(wěn)定性影響[J]. 電力系統(tǒng)保護與控制,2011,39(3):7-11.
[4] 遲永寧,王偉勝,劉燕華,等. 大型風(fēng)電場對電力系統(tǒng)暫態(tài)穩(wěn)定性的影響[J]. 電力系統(tǒng)自動化,2006,30(15):10-14.
[5] 倪以信,陳壽孫,張寶霖.動態(tài)電力系統(tǒng)的理論和分析[M].北京:清華大學(xué)出版社,2002.
[6] 郭成,李群湛,王德林. 互聯(lián)電力系統(tǒng)低頻振蕩的廣域Prony 分析[J]. 電力自動化設(shè)備,2009,29(5):69-73.