一種新型直流電源監(jiān)控系統(tǒng)的設(shè)計(jì) 

楊小琴1,王波2,包林杰2, 朱大衛(wèi)2 
(1 華東建筑設(shè)計(jì)研究院有限公司,上海 200002;
2 江蘇安科瑞電器制造有限公司,江蘇 無錫 214400)
 
 

摘 要: 介紹了一款無人職守的智能直流電源監(jiān)控系統(tǒng),闡述了綜合監(jiān)控模塊、電池巡檢模塊和絕緣監(jiān)測模塊。該系統(tǒng)采用分散控制、集中管理的模塊化方式,能自動檢測直流電源系統(tǒng)的各種數(shù)據(jù),并對系統(tǒng)故障進(jìn)行實(shí)時監(jiān)測及報(bào)警,實(shí)現(xiàn)蓄電池的智能管理,較好地滿足了無人值守變電站及配網(wǎng)自動化的需求。
關(guān)鍵詞: 直流電源系統(tǒng);實(shí)時監(jiān)測;模塊化
中圖分類號:TM933 文獻(xiàn)標(biāo)識碼:A 文章編號:1007-3175(2014)05-0026-03


Design of New Type of Direct Current Power Supply Supervisory Control System 

YANG Xiao-qin1, WANG Bo2, BAO Lin-jie2, ZHU Da-wei2 
(1 East China Architectural Design & Research Institute Co., Ltd, Shanghai 200002, China;
2 Jiangsu Acrel Co., Ltd, Wuxi 214400, China)
 
 

Abstract: Introduction was made to an unattended intelligent DC power supply supervisory control system. This paper expounded the module of synthetized monitoring, the module of battery polling and the module of insulation monitoring. The system adopted the modularized modes of decentralized control and centralized management, being able to detect a variety of data of direct current power supply systems automatically and carrying out monitoring and alarming in real time, which realizes the intelligent management for storage batteries, so as to meet the requirements of unattended operation for automation of transformer substation and distribution network.
         Key words: direct current power supply system; real-time monitor; modularization


參考文獻(xiàn)
[1] 鄒甲,王禮帥,喬黎,等.電力直流屏用智能充電電源的研制[J].電源世界,2008(5):32-35.
[2] 呂志寧,楊忠亮.變電站直流監(jiān)控系統(tǒng)的實(shí)現(xiàn)[J].廣東電力,1999,12(3):13-15.
[3] 李利森,徐彥.電力系統(tǒng)用微機(jī)監(jiān)控直流電源[J].電源技術(shù)應(yīng)用,2001,4(7):347-350.
[4] 王新,杜慶楠,陳立香,崔景岳. 變電站直流系統(tǒng)微機(jī)監(jiān)測控制裝置的研究[J]. 焦作工學(xué)院學(xué)報(bào),1999,18(5):372-375.
[5] 馬福舟,楊順江,徐莉,董克儉.分散式直流屏蓄電池監(jiān)控系統(tǒng)[J].電源技術(shù),2008(5):69-70.
[6] 呂勇軍.智能蓄電池在線監(jiān)測儀的設(shè)計(jì)[J].國外電子元器件,2001(9):55-57.
[7] 徐天奇,蔡駿峰.直流系統(tǒng)接地故障判斷和定位裝置的設(shè)計(jì)[J].儀表技術(shù),2011(12):7-8.
[8] 君懷,陳怡歡.直流絕緣監(jiān)測的應(yīng)用與發(fā)展[J].高壓電器,2000,36(6):47-49.
[9] 向小民,胡翔勇,曾維魯,高學(xué)軍.直流系統(tǒng)絕緣監(jiān)察裝置[J].中國電力,1999,32(8):38-39.
[10] 周振雄,張艷萍.變電站直流系統(tǒng)接地檢測儀的研制[J].北華大學(xué)學(xué)報(bào):自然科學(xué)版,2001,2(1):84-88.