Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 文章瀏覽排名

油浸式變壓器冷卻系統(tǒng)節(jié)能運行控制策略研究

來源:電工電氣發(fā)布時間:2016-04-06 12:06 瀏覽次數(shù):17

油浸式變壓器冷卻系統(tǒng)節(jié)能運行控制策略研究 

高榮貴1,馮智倩1,余鵬1,趙蓉1,秦鑫1,王珊珊2 
1 太原供電公司,山西 太原 030012;2 國網(wǎng)電力科學研究院,湖北 武漢 430074 
 

摘 要:針對現(xiàn)有冷卻器控制方式的不足,基于熱電類比理論建立了變壓器熱路模型,結(jié)合環(huán)境溫度及冷卻方式變化時模型參數(shù)的不同求取方法,制定了高效節(jié)能的冷卻器運行策略。在準確計算變壓器熱點溫度的基礎上,借助高可靠性、高精度的光纖溫度傳感器來獲得變壓器端部油溫,并結(jié)合冷卻器節(jié)能運行控制策略,有效避免了冷卻器冷卻能力過?,F(xiàn)象,保證了變壓器安全、穩(wěn)定、經(jīng)濟運行。
關鍵詞:油浸式變壓器;熱電類比法;節(jié)能環(huán)保;熱點溫度;冷卻系統(tǒng)
中圖分類號:TM411 文獻標識碼:A 文章編號:1007-3175(2014)08-0034-04


Study on Energy Saving Operation Control Strategy of Oil-Immersed Transformer Cooling System 

GAO Rong-gui1, FENG Zhi-qian1, YU Peng1, ZHAO Rong1, QIN Xin1, WANG Shan-shan2 
1 Taiyuan Power Supply Company, Taiyuan 030012, China; 
2 State Grid Electric Power Research Institute, Wuhan 430074, China
 
 

Abstract: Aiming at insufficiency of the existing cooler control method, this paper built up a transformer thermal route model based on the thermoelectricity analogy method. Combined with different obtaining method in changes of environment temperature and cooling means, highly effective energy saving cooler operation strategy was made. On the basis of correct transformer thermal point temperature calculation, the fiber temperature sensor with high reliability and high accuracy could obtain transformer’s end part oil temperature value. Combined with cooler energy saving operation strategy, the system has effectively avoided cooler’s cooling capacity surplus situation, to have ensured transformer in safe, stable and economic operation.
           Key words: oil-immersed transformer; thermoelectricity analogy method; energy saving and environmental protection; thermal point temperature; cooling system


[1] 程曉東,顧黎明,周晨.智能變壓器冷卻器控制系統(tǒng)的應用[J].浙江電力,2010(8):9-11. 
[2] 鄧世杰.大型變壓器風冷卻系統(tǒng)的自動控制[J].變壓器,2003,40(10):23-25.
[3] 劉鑒民.傳熱傳質(zhì)原理及其在電力科技中的應用分析[M].北京:中國電力出版社,2006.
[4] 湯焱,劉成遠,郝忠言,等.變壓器繞組熱點溫升的計算與實驗研究[J].變壓器,2001,38(2):1-5. 
[5] 江淘莎,李劍,陳偉根,等.油浸式變壓器繞組熱點溫度計算的熱路模型[J].高電壓技術,2009,35(7):1635-1640.
[6] 趙蓉,馮智倩,高榮貴,等.油浸式變壓器頂層油溫熱路模型計算分析與檢驗[J].電工電氣,2014(2):56-60.