Suzhou Electric Appliance Research Institute
期刊號: CN32-1800/TM| ISSN1007-3175

Article retrieval

文章檢索

首頁 >> 文章檢索 >> 文章瀏覽排名

電動機(jī)起動時電網(wǎng)電壓降的公式與仿真計(jì)算比較

來源:電工電氣發(fā)布時間:2016-08-18 14:18 瀏覽次數(shù):12
電動機(jī)起動時電網(wǎng)電壓降的公式與仿真計(jì)算比較
 
張曼,牛濤,郭學(xué)英
(江蘇省電力設(shè)計(jì)院,江蘇 南京 211102)
 
    摘 要:介紹了工程中常用的兩種公式計(jì)算電網(wǎng)母線電壓降的方法,以某工廠電動機(jī)負(fù)荷接入系統(tǒng)起動為例進(jìn)行仿真,分析了起動時間、起動功率因數(shù)等對母線電壓降的影響。公式與仿真計(jì)算比較表明,母線短路容量越大,公式與仿真計(jì)算電壓降結(jié)果越接近;公式計(jì)算方法的輸入條件僅為電網(wǎng)及電動機(jī)的一些穩(wěn)態(tài)參數(shù),無法體現(xiàn)起動時間、起動功率因數(shù)等對母線電壓降的影響;工程實(shí)際應(yīng)用中如果數(shù)據(jù)充分,建議采用仿真方法計(jì)算電動機(jī)起動時電網(wǎng)母線電壓降。
    關(guān)鍵詞:電動機(jī)起動;電壓降;仿真計(jì)算;公式計(jì)算
    中圖分類號:TM32;TM744   文獻(xiàn)標(biāo)識碼:A   文章編號:1007-3175(2016)08-0015-04
 
Comparison on Formula and Simulation Calculation of
Grid Voltage Drop at Time of Motor Starting
 
ZHANG Man, NIU Tao, GUO Xue-ying
(Jiangsu Electric Power Design Institute, Nanjing 2111 02, China)
 
    Abstract: Introduction was made to two commonly used methods in practical engineering for calculating grid busbar voltage drop. This paper took the motor load access system starting of a factory for example and carried out simulation. Analysis was made to the starting time and the starting power factor etc impacts of busbar voltage drop. The calculation and comparison of formula and simulation show that the larger the busbar short-circuit capacity is, the smaller the difference between formula and simulation of voltage drop is. The input conditions of formula calculation are just some steady state parameters of grid and motor, so they cannot reflect the influence of some other parameters on grid voltage drop, such as the starting time and the starting power factor and so on. This paper recommends that the simulation method can be adopted in practical engineering to get grid voltage drop if the condition allows.
    Key words: motor starting; voltage drop; simulation calculation; formula calculation
 
參考文獻(xiàn)
[1] 趙兵,湯涌. 感應(yīng)電動機(jī)負(fù)荷的動態(tài)特性分析[J]. 中國電機(jī)工程學(xué)報,2009,29(7):71-77.
[2] 趙猛,鄒繼斌,胡建輝,等. 異步起動永磁同步電動機(jī)起動特性研究[J]. 電工技術(shù)學(xué)報,2007,22(7):145-149.
[3] GB/T 12325—2008 電能質(zhì)量 供電電壓偏差[S].
[4] GB/T 12326—2008 電能質(zhì)量 電壓波動和閃變[S].
[5] GB 50055—2011 通用用電設(shè)備配電設(shè)計(jì)規(guī)范[S].
[6] 戈寶軍,李波,李發(fā)海,等. 同步電機(jī)異步-同步起動過程分析[J]. 中國電機(jī)工程學(xué)報,2005,25(5):93-97.
[7] 胡浩,肖津. 高壓電動機(jī)的起動方案及設(shè)計(jì)[J].電工電氣,2010(3):25-28.
[8] 張建華,楊鵬,史旺旺. 三相異步電動機(jī)起動過程仿真分析[J]. 中小型電機(jī),2002,29(6):10-13.
[9] 邢穎,李寶樹,程佳. 異步電動機(jī)起動過程的電壓暫降分析[J]. 電氣應(yīng)用,2008,27(15):79-83.
[10] 任元會,卞鎧生,姚家祎. 工業(yè)與民用配電設(shè)計(jì)手冊[K]. 北京:中國電力出版社,2005.