提高變電站監(jiān)控信息規(guī)范率

來源:電工電氣發(fā)布時間:2017-02-18 08:18 瀏覽次數(shù):8
提高變電站監(jiān)控信息規(guī)范率
 
曹娜,房藝丹,徐志靜
(國網(wǎng)吳忠供電公司,寧夏 吳忠 751100)
 
    摘 要:提高變電站監(jiān)控信息規(guī)范率,可有效提升監(jiān)控效率。選取17 座變電站進(jìn)行統(tǒng)計分析,發(fā)現(xiàn)造成變電站監(jiān)控信息規(guī)范率低的主要原因是監(jiān)控信息點(diǎn)表標(biāo)準(zhǔn)不統(tǒng)一。依據(jù)《變電站監(jiān)控系統(tǒng)信息采集規(guī)范》和《變電站典型信息表》,結(jié)合地區(qū)電網(wǎng)情況,編制各電壓等級的變電站典型信息點(diǎn)表,并根據(jù)典型信息點(diǎn)表優(yōu)化各站監(jiān)控信息。經(jīng)實(shí)際驗(yàn)證,有效提升了變電站監(jiān)控信息的規(guī)范率。
    關(guān)鍵詞:變電站;監(jiān)控信息;規(guī)范率;典型信息點(diǎn)表
    中圖分類號:TM63       文獻(xiàn)標(biāo)識碼:A       文章編號:1007-3175(2017)02-0063-04
 
Improved Standard Rate of Substation Monitoring Information
 
CAO Na, FANG Yi-dan, XU Zhi-jing
(State Grid Wuzhong Power Supply Company, Wuzhong 7511 00, China)
 
    Abstract: The improved standard rate of substation monitoring information could raise the monitoring efficiency. The seventeen substations were carried out statistical analysis. The main reason causing the low substation monitoring information standard rate was disunity monitoring information point table standard. According to substation monitoring information collection standard and substation typical information table, combined with the regional power grid situation, substation typical information point tables of every voltage classes were established, and each substation monitoring information was optimized according to the information point tables. The practical verification improves the standard rate of substation monitoring information effectively.
    Key words: substation; monitoring information; standard rate; typical information point table
 